Deskripsi
ShineWayTech MTP-50 Series Multi-Functional Handheld OTDR
Compact, Versatile, Easy-to-use, Cost-effective OTDR
MTP-50 series OTDR offers more testing capacities, flexibility and value with combination of optical fiber testing and RJ45 cable testing functions together which includes Auto OTDR, Expert OTDR, Link Image, Optical Power Meter, Stabilized Laser Source, Optical Loss Test, Visual Fault Locator, RJ45 Cable Length, RJ45 Cable Sequence and RJ45 Cable Tracker. With considerate function of LED flashlight and high capacity of 6600mAh lithium battery, it helps the technicians operate OTDR in dark environment and at remote work site without worrying about running out of battery power. MTP-50 series OTDR is your ideal test instrument for optical fiber installation and maintenance which meets various testing requirements of entire fiber network.
Features
- Compact, handheld, lightweight & easy to use
- 5 inch capacitive touch screen for easily operation and quick response
- Fast boot-up for fiber troubleshooting and restoration
- Multi-tasking operation which can perform OTDR, OPM and VFL function simultaneously
- Dual wavelength testing with dynamic range of 24/22dB
- Short-distance performance with 1.5m event dead zone and 8m attenuation dead zone
- Auto OTDR/Expert OTDR/Averaging/Real time test
- Link Image – smart Icon-based map view by multi pulse widths acquisition
- Built-in Stabilized Laser Source, Optical Power Meter, Optical Loss Testing and VFL
- Optional RJ45 cable testing function supported: RJ45 cable length, RJ45 cable sequence and RJ45 cable tracker (Available for ADVANCED models)
- Pass/Fail assessment and ORL test function
- 8G memory card, supporting more than 200,000 test records storage
- OTDR trace file generation (.sor)
- PC software for batch data processing
- USB power charging and data transfer
- Screenshot easily in any interface
- 8 hrs continuous operation/20 hrs standby
Specifications
Model (1) |
BASIC |
ADVANCED |
MTP-50-S20A |
MTP-50-S20A-R |
|
Wavelength | 1310/1550nm±20nm | |
Dynamic Range (2) | 24/22dB | |
Event Dead Zone (3) | 1.5m | |
Distance Range | 0.5, 1, 2, 4, 8, 16, 32, 64, 100KM | |
Pulse Width | 3ns – 20us | |
Averaging Time | 5s, 15s, 30s, 1min, 2min, 3min | |
Distance Measure Accuracy | ± (1m + 5×10-5×distance + sampling space) | |
Attenuation Detect Accuracy | ±0.05 dB/ dB | |
Reflection Detect Accuracy | ±3 dB | |
Sampling Resolution | 0.05 – 8m | |
Refractive Index | 1.00000 – 2.00000 | |
Loss Resolution | 0.001dB | |
Loss Threshold | 0.01dB | |
Connector | FC/UPC (Interchangeable SC, ST) | |
Multi-tasking | Support | |
General Specifications | ||
Display | 5 inch colour LCD, Multi-touch capacitive touchscreen | |
Power Supply | Lithium Battery: 3.7V, 6600mAh AC Adapter: 5VDC, 2A |
|
Battery Life | 8 hours continuous operation, 20 hours standby | |
Data Storage | 8G, ≥ 200,000 records | |
Data Interface | USB Type C | |
Operating Temperature | -10°C – 50°C | |
Storage Temperature | -40°C – 70°C | |
Relative Humidity | 0 – 95% (non-condensing) | |
Weight | 0.7kg (Including battery) | |
Dimensions (H×W×T) | 190×130×65mm | |
Visual Fault Locator | ||
Wavelength | 650nm ±20nm | |
Output Power | ≥ 10mW | |
MOD | CW/1Hz/2Hz | |
Connector | Universal 2.5mm | |
Stabilized Laser Source | ||
Wavelength | Same as OTDR working wavelength (4) | |
Output Power | ≥ -5dBm (adjustable) | |
MOD | CW/270/330/1K/2KHz | |
Stability | CW, ±0.5dB/15min (After 15 min warming up) | |
Connector | FC/UPC (Interchangeable SC, ST) | |
Optical Power Meter | ||
Calibrated Wavelength | 850, 1300, 1310, 1490, 1550, 1625, 1650nm | |
Power Range | -50 – +26dBm | |
Detector Type | InGaAs | |
Display Resolution | 0.01dB | |
Accuracy | ± 5% | |
Frequency Identification | CW/270/330/1K/2KHz | |
Connector | Universal 2.5mm | |
Optical Loss Test | ||
Stabilized Laser Source | Same as SLS Module | |
Optical Power Meter | Same as OPM Module | |
Detector Type | InGaAs | |
Display Resolution | 0.01dB | |
Accuracy | ± 5% | |
Frequency Identification | CW/270/330/1K/2KHz | |
Connector | Universal 2.5mm | |
Optical Loss Test | ||
Stabilized Laser Source | Same as SLS Module | |
Optical Power Meter | Same as OPM Module | |
IL Test | Support | |
RJ 45 Cable Length Test (5) | ||
Test Distance | ≥ 300m | |
RJ 45 Cable Sequence Test (5) | ||
Sequence Test | Support | |
RJ 45 Cable Tracker (5) | ||
Mode | Digital tracking | |
Distance | ≥ 300m | |
Online/Line Pair Tracking | Support | |
Ordering Information | ||
Standard Package Includes | Instrument, Lithium Battery, USB Data cable, AC adaptor, Warranty Card, Production Test Report, Soft Carrying Case |
* Specifications subject to change without notice
Notes:
(1) Specifications describe the instrument’s warranted performance, measured with typical UPC type connectors. Uncertainties due to the refractive index of fiber are not considered.
(2) The dynamic range is measured at maximum pulse width and averaging time of 3 minutes.
(3) Conditions for dead zone measurement: minimum range, minimum pulse width, reflection intensity is less than -45dB, typical value.
(4) Stabilized laser source shares OTDR optical port and work on the same OTDR wavelength.
(5) Visual Fault Locator, Stabilized Laser source, Optical Power Meter, Optical Loss Test is standard on BASIC and ADVANCED models. RJ45 cable length, RJ45 cable sequence and RJ45 cable tracker is standard on ADVANCED models only.
ShineWayTech MTP-50 Series OTDR – Datasheet
Ulasan
Belum ada ulasan.