SPECIFICATIONS | ||||||||||
ASR-3200 | ASR-3300 | ASR-3400 | ASR-3400HF | |||||||
INPUT RATING (AC) | ||||||||||
Nominal Input Voltage | 200V AC to 240V AC | |||||||||
Input Voltage Range | 18V AC to 264V AC | |||||||||
Phase | Single phase, Two-wire | |||||||||
Nominal Input Frequency | 50Hz to 60Hz | |||||||||
Input Frequency Range | 47Hz to 63Hz | |||||||||
Max. Power Consumption | 2500VA or less | 3750VA or less | 5000VA or less | 5000VA or less | ||||||
Power factor*1 | 200V AC | 0.95 (TYP) | ||||||||
Max. Input Current | 200V AC | 15A | 22.5A | 30A | 30A | |||||
*1. For an output voltage of 100V / 200V (100V / 200V range), maximum current, and a load power factor of 1. | ||||||||||
AC MODE OUTPUT RATINGS (AC rms) | ||||||||||
Voltage | Setting Range*1 | 0.0V to 200.0V / 0.0V to 400.0V | ||||||||
Setting Resolution | 0.1V | |||||||||
Accuracy*2 | ±(1 % of set + 1V / 2V) | |||||||||
Output Phase | Single phase, Two-wire | |||||||||
Maximum Current*3 | 100V | 20A | 30A | 40A | 40A | |||||
200V | 10A | 15A | 20A | 20A | ||||||
Maximum Peak Current*4 | 100V | 120A | 180A | 240A | 160A | |||||
200V | 60A | 90A | 120A | 80A | ||||||
Load Power Factor | 0 to 1 (leading phase or lagging phase) | |||||||||
Power Capacity | 2000VA | 3000VA | 4000VA | 4000VA | ||||||
Frequency | Setting Range | AC Mode: 40.0Hz to 999.9Hz, AC+DC Mode: 1Hz to 999.9Hz |
AC Mode: 40.0Hz to 5000Hz, AC+DC Mode: 1Hz to 5000Hz |
|||||||
Setting Resolution | 0.01Hz (1.00 to 99.99Hz), 0.1Hz (100.0 to 999.9Hz) |
0.01Hz (1.00 to 99.99Hz), 0.1Hz (100.0 to 999.9Hz) 1Hz (1000 to 5000Hz) |
||||||||
Accuracy | 0.02% of set (23°C ± 5°C) | |||||||||
Stability*5 | ±0.005% | |||||||||
Output on Phase | 0° to 359° variable (setting resolution 1°) | |||||||||
DC Offset*6 | Within ± 20mV (TYP) | |||||||||
*1. 100V / 200V range *2. For an output voltage of 20V to 200V / 40V to 400V, an output frequency of 45Hz to 65Hz, no load, and 23°C ± 5°C *3. For an output voltage of 1V to 100V / 2V to 200V. Limited by the power capacity when the output voltage is 100V to 200V / 200V to 400V. If there is the DC superimposition, the current of AC+DC mode satisfies the maximum current. In the case of lower than 40Hz, and the power rating temperature, the maximum current will be decrease. *4. With respect to the capacitor-input rectifying load. Limited by the maximum current. *5. For 45Hz to 65Hz, the rated output voltage, no load and the resistance load for the maximum current, and the operating temperature. *6. In the case of the AC mode and 23°C ± 5°C. |
||||||||||
OUTPUT RATING FOR DC MODE | ||||||||||
Voltage | Setting Range*1 | -285V to +285V / -570V to +570V | ||||||||
Setting Resolution | 0.1V | |||||||||
Accuracy*2 | ±(1% of set + 1V / 2V) | |||||||||
Maximum Current*3 | 100V | 20A | 30A | 40A | 40A | |||||
200V | 10A | 15A | 20A | 20A | ||||||
Maximum Peak Current*4 | 100V | 120A | 180A | 240A | 160A | |||||
200V | 60A | 90A | 120A | 80A | ||||||
Power Capacity | 2000W | 3000W | 4000W | 4000W | ||||||
*1. 100V / 200V range *2. For an output voltage of -285V to -28.5V, +28.5V to +285V / -570V to -57V, +57V to +570V, no load, and 23°C ± 5°C *3. For an output voltage of 1.4V to 100V / 2.8V to 200V. Limited by the power capacity when the output voltage is 100V to 250V / 200V to 500V. *4. Limited by the maximum current. |
||||||||||
OUTPUT VOLTAGE STABILITY | ||||||||||
Line regulation*1 | 0.2% or less | |||||||||
Load regulation*2 | 0.5% or less (0 to 100%, via output terminal) | |||||||||
Ripple noise*3 | 1 Vrms / 2 Vrms (TYP) | |||||||||
*1. Power source input voltage is 200V, 220V, or 240V, no load, rated output. *2. For an output voltage of 100V to 200V / 200V to 400V, a load power factor of 1, stepwise change from an output current of 0 A to maximum current (or its reverse), using the output terminal on the rear panel. *3. For 5Hz to 1MHz components in DC mode using the output terminal on the rear panel. |
||||||||||
OUTPUT VOLTAGE WAVEFORM DISTORTION RATIO, OUTPUT VOLTAGE RESPONSE TIME, EFFICIENCY | ||||||||||
Total Harmonic Distortion (THD)*1 | < 0.2% @ 50/60Hz < 0.3% @ <500Hz < 0.5% @ 500.1Hz ~ 999.9Hz |
< 0.2% @ 50/60Hz < 0.5% @ <500Hz < 1.0% @ 500.1Hz ~ 2000Hz < 2.0% @ 2001Hz ~ 5000Hz |
||||||||
Output Voltage Response Time*2 | 100μs (TYP) | |||||||||
Efficiency*3 | 80 % or more | |||||||||
*1. At an output voltage of 50V to 200V / 100V to 400V, a load power factor of 1, and in AC mode. *2. For an output voltage of 100V / 200V, a load power factor of 1, with respect to stepwise change from an output current of 0 A to the maximum current (or its reverse). *3. For AC mode, at an output voltage of 100V / 200V, maximum current, and load power factor of 1. |
||||||||||
MEASURED VALUE DISPLAY | ||||||||||
Voltage | RMS, AVG Value*1 | Resolution | 0.1V | |||||||
Accuracy*2 | For 45Hz to 65Hz and DC: ±(0.5% of reading + 0.5V / 1V) For all other frequencies: ±(0.7% of reading + 1V / 2V) |
|||||||||
PEAK Value | Resolution | 0.1V | ||||||||
Accuracy | For 45Hz to 65Hz and DC: ±(|2 % of reading| + 1V / 2V) | |||||||||
Current | RMS, AVG Value | Resolution | 0.01A | |||||||
Accuracy*3 | For 45Hz to 65Hz and DC: ±(0.5% of reading + 0.1A/0.05A) For all other frequencies: ±(0.7 % of reading + 0.2A/0.1A) |
For 45Hz to 65Hz and DC: ±(0.5% of reading + 0.15A/0.08A) For all other frequencies: ±(0.7 % of reading + 0.3A/0.15A) |
For 45Hz to 65Hz and DC: ±(0.5 % of reading + 0.2A/0.1A) For all other frequencies: ±(0.7% of reading + 0.4A/0.2A) |
|||||||
PEAK Value | Resolution | 0.1A | ||||||||
Accuracy*4 | For 45Hz to 65Hz and DC: ±(|2% of reading| + 0.5A/0.25A) |
For 45Hz to 65Hz and DC: ±(|2% of reading| + 0.8A/0.4A) |
For 45Hz to 65Hz and DC: ±(|2% of reading| + 1A/0.5A) |
|||||||
Power | Active (W) | Resolution | 1W | |||||||
Accuracy*5 | ±(2% of reading + 2W) | ±(2% of reading + 3W) | ±(2% of reading + 4W) | |||||||
Apparent (VA) | Resolution | 1VA | ||||||||
Accuracy*5*6 | ±(2% of reading + 2VA) | ±(2% of reading + 3VA) | ±(2% of reading + 4VA) | |||||||
Reactive (VAR) | Resolution | 1VAR | ||||||||
Accuracy*5*7 | ±(2% of reading + 2VAR) | ±(2% of reading + 3VAR) | ±(2% of reading + 4VAR) | |||||||
Load Power Factor | Range | 0.000 to 1.000 | ||||||||
Resolution | 0.001 | |||||||||
Load Crest Factor | Range | 0.00 to 50.00 | ||||||||
Resolution | 0.01 | |||||||||
Harmonic Voltage Effective Value (rms) Percent (%) (AC-INT and 50/60Hz only) |
Range | Up to 100th order of the fundamental wave | ||||||||
Full Scale | 200V / 400V, 100% | |||||||||
Resolution | 0.1V, 0.1% | |||||||||
Accuracy*8 | Up to 20th ±(0.2% of reading + 0.5V / 1V) 20th to 100th ±(0. % of reading + 0.5V / 1V) |
|||||||||
Harmonic Current Effective Value (rms) Percent (%) (AC-INT and 50/60Hz only) |
Range | Up to 100th order of the fundamental wave | ||||||||
Full Scale | 20A / 10A, 100% | 30A / 15A, 100% | 40A / 20A, 100% | |||||||
Resolution | 0.01A, 0.1% | |||||||||
Accuracy*3 | Up to 20th ±(1% of reading + 0.4A/0.2A) 20th to 100th ±(1.5% of reading + 0.4A/0.2A) |
Up to 20th ±(1% of reading+0.6A/0.3A) 20th to 100th ±(1.5% of reading + 0.6A/0.3A) |
Up to 20th ±(1% of reading + 0.8A/0.4A) 20th to 100th ±(1.5% of reading + 0.8A/0.4A) |
|||||||
*1. The voltage display is set to RMS in AC/AC+DC mode and AVG in DC mode. *2. AC mode: For an output voltage of 20 V to 200 V / 40 V to 400 V and 23°C ±5°C. DC mode: For an output voltage of 28.5V to 285V / 57V to 570V and 23°C ± 5°C. *3. An output current in the range of 5% to 100% of the maximum current, and 23°C ±5°C. *4. An output current in the range of 5% to 100% of the maximum peak current in AC mode, an output current in the range of 5% to 100% of the maximum instantaneous current in DC mode, and 23°C ± 5°C. The accuracy of the peak value is for a waveform of DC or sine wave *5. For an output voltage of 50V or greater, an output current in the range of 10% to 100% of the maximum current, DC or an output frequency of 45Hz to 65Hz, and 23°C ±5°C. *6. The apparent and reactive powers are not displayed in the DC mode. *7. The reactive power is for the load with the power factor 0.5 or lower. *8. An output voltage in the range of 20V to 200V / 40V to 400V and 23°C ±5°C. |
||||||||||
OTHER | ||||||||||
Protections | UVP, OCP, OTP, OPP, Fan Fail | |||||||||
Display | TFT-LCD, 4.3 inch | |||||||||
Memory Function | Store and recall settings, Basic settings: 10 (0~9 numeric keys) | |||||||||
Arbitrary Wave | Number of Memories | 16 (nonvolatile) | ||||||||
Waveform Length | 4096 words | |||||||||
Interface | Standard | USB | Type A: Host, Type B: Slave, Speed: 1.1/2.0, USB-CDC, USB-TMC | |||||||
LAN | MAC Address, DNS IP Address, User Password, Gateway IP Address, Instrument IP Address, Subnet Mask | |||||||||
RS-232C | Complies with the EIA-RS-232 specifications | |||||||||
EXT Control | External Signal Input External Control I/O |
|||||||||
GPIB | SCPI-1993, IEEE 488.2 compliant interface | |||||||||
Insulation Resistance Between input and chassis, output and chassis, input and output |
500V DC, 30 MΩ or more | |||||||||
Withstand Voltage Between input and chassis, output and chassis, input and output |
1500V AC, 1 minute | |||||||||
EMC | EN 61326-1, EN 61326-2-1, EN 61000-3-2, EN 61000-3-3 EN 61000-3-11, EN 61000-3-12 EN 61000-4-2/-4-3/-4-4/-4-5/-4-6/-4-8/-4-11/-4-34 EN 55011 (Class A), EN 55032 |
|||||||||
Safety | EN 61010-1 | |||||||||
Environment | Operating Environment | Indoor use, Overvoltage Category II | ||||||||
Operating Temperature Range | 0°C to 40°C | |||||||||
Storage Temperature Range | -10°C to 70°C | |||||||||
Operating Humidity Range | 20% to 80% RH (no condensation) | |||||||||
Storage Humidity Range | 90% RH or less (no condensation) | |||||||||
Altitude | Up to 2000m | |||||||||
Dimensions & Weight | 430(W)×176(H)×530(D) (not including protrusions); Approx. 25kg | |||||||||
Specifications subject to change without notice.
ORDERING INFORMATION |
ASR-3200 2kVA Programmable AC/DC Power Source ASR-3300 3kVA Programmable AC/DC Power Source ASR-3400 4kVA Programmable AC/DC Power Source ASR-3400HF 4kVA Programmable AC/DC Power Source |
ACCESSORIES |
CD (User manual/Programming manual), Safety Guide, Input Terminal Cover, Output Terminal Cover Include Remote Sensing, GRA-442-E Rack Mount Adapter (EIA), GTL-246 USB Cable |