Deskripsi
Fluke 365 Detachable Jaw True RMS AC/DC Clamp Meter
Be ready for anything.
The Fluke 365 is a rugged meter perfect for jobs where access to wires is difficult. The 365’s thin, small jaw is detachable with a flexible lead, which makes gaining access to wires and viewing the display easier than ever.
Features
- 200A AC and DC current measurement with detachable jaw
- 600V AC and DC voltage measurement
- Detachable jaw makes accessing wires and viewing the display easier
- Built in flashlight/torch allows for easy illumination and identification of wires
- CAT III 600V
- Compact design fits in your hand and can be used while wearing protective equipment
- State of the art signal processing allows for use in noisy electrical environments while providing stable readings
- Large, easy to read, backlight display automatically sets the correct measurement range so you do not need to change switch positions while taking a measurement
- Soft carrying case
Specification
Electrical Specifications |
|
| AC Current | |
| Range | 200.0 A |
| Resolution | 0.1 A |
| Accuracy | 2 % ±5 digits (45 – 65 Hz) |
| 2.5 % ±5 digits (65 – 400 Hz) | |
| Crest Factor | 2.5 @ 125 A |
| 1.55 @ 200 A | |
| Add 2 % for C.F. >2 | |
| DC Current | |
| Range | 200.0 A |
| Resolution | 0.1 A |
| Accuracy | 2 % ±5 digits |
| AC Voltage | |
| Range | 600.0 V |
| Resolution | 0.1 V |
| Accuracy | 1.5 % ±5 digits (45 – 400 Hz) |
| DC Voltage | |
| Range | 600.0 V |
| Resolution | 0.1 V |
| Accuracy | 1 % ±5 digits |
| Resistance | |
| Range | 600.0 Ω/6000 Ω |
| Resolution | 0.1 Ω/1 Ω |
| Accuracy | 1 % ±5 digits |
Mechanical Specifications |
|
| Size (L x W x H) | 225 x 65 x 46 mm |
| 225 x 65 x 46 mm | 275 g (including batteries) |
| Jaw Opening | 18 mm |
| Detachable Jaw Cable Length | 900 mm |
Environmental Specifications |
|
| Operating Temperature | -10 °C to +50 °C |
| Storage Temp | -40 °C to +60 °C |
| Operating Humidity | Non condensing (<10 °C) |
| ≤90 % RH (at 10 °C to 30 °C) | |
| ≤75 % RH (at 30 °C to 40 °C) | |
| ≤45 % RH (at 40 °C to 50 °C) | |
| (Without Condensation) | |
| Operating Altitude | 2000 meters |
| Storage Altitude | 12,000 meters |
| Temperature Coefficients | 0.1 x(specified accuracy)/ °C (<18 °C or > 28 °C) |
| Safety Compliance | ANSI/ISA S82.02.01:2004 |
| CAN/CSA-C22.2 No. 61010-1-04 | |
| UL 61010-1:2004 | |
| EN/IEC 61010-1:2001 to 600V CAT III | |
| Pollution Degree 2 | |
| Batteries | 2 AA, NEDA 15A, IEC LR6 |


Ulasan